tehama-wireless-automated-meter-reading-runtime-mdt-standard-range

MDT

Metering Data Transceiver with Runtime Measurement

Standard and MAX Range Systems

Product Overview

The Tehama Wireless Runtime MDT records the “On” time in seconds of various distributed energy measurements. It comes in two versions, our Standard and MAX Range. The Standard Range is our original, first generation system, which we continue to fully support and maintain.

The running count is stored and transmitted to the DCAP once an hour. Versions of the Runtime MDT detect a 24VAC thermostat control state or a dry contact/relay switch input.

Optionally the unit can be ordered with an internal temperature sensor for ambient readings or external thermistor with the dry contact version. The thermostat version also detects the integrity of the connection and will generate an alert if the connection has been tampered with.

The unit is powered by two AA batteries providing a five to seven year battery life under normal conditions. An optional line powered variation is also available for the dry contact switch version.

The local MDT time base for time stamping data is driven by a highly accurate watch crystal and is regularly updated from the DCAP via the RF network.

Specifications

Specification Details
Inputs Options • 24 VAC zone value/thermostat control signals
• Dry Contact (Relay) from control signal
• Internal thermistor temperature sensor
• External thermistor temperature sensor
Data Resolution 1 hour reading and transmission interval
Radio Frequency: 902 – 928 MHz; FCC Certified
Standard (TW-160): 10mW, Open field range over 1 mile*
Max (TW-170): 80mW, Open Field range approaching 10 miles*
LED Bi-color LED Indicates on/off and RF network connection quality
Operating Environment -20 to 145 degree F, up to 90% RH, non-condensing
Power • Two AA Alkaline (standard)
• Two AA Lithium (Optional, for sub-freezing temperatures)
• 2.5 to 3.3V DC input (L3-RC versions)
Typical Battery Life 5 to 7 years @ 50º to 90º F, Reduced at extreme temperatures
Dimensions 3.5” x 2.1” x 1.2”
Warranty Five years. For more detailed information, please visit our warranty page. Note that the warranty does not cover batteries.

Continual product enhancements may cause specifications to change without notice.
*Actual range may vary depending on installation location and topography.

Models

Standard System Model Number Description
24VAC input Runtime MDT, Battery powered TW-160B-R
TW-160B-RI
-R: 24VAC thermostat control runtime counter, Counts number of seconds circuit is energized and circuit fault. 1-hr interval RF transmissions.
-RI: Adds internal temperature measurement
Dry contact input Runtime MDT, Battery powered TW-160B-RC
TW-160B-RCI
TW-160B-RCX
-RC: Relay control signal runtime counter. Counts number of seconds relay input is closed 1-hr interval RF transmissions.
-RCI: Adds internal temperature measurement
-RCX: Add external thermistor support (thermistor sold separately)
Dry contact input Runtime MDT, Line powered TW-160LC-RC(I) Same functions as battery models but uses external DC 2.5 to 3.3V external power source
MAX System Model Number Description
24VAC input Runtime MDT, Battery powered TW-170B-R
TW-170B-RI
-R: 24VAC thermostat control runtime counter, Counts number of seconds circuit is energized and circuit fault. 1-hr interval RF transmissions.
-RI: Adds internal temperature measurement
Dry contact input Runtime MDT, Battery powered TW-170B-RC
TW-170B-RCI
TW-170B-RCX
-RC: Relay control signal runtime counter. Counts number of seconds relay input is closed 1-hr interval RF transmissions.
-RCI: Adds internal temperature measurement
-RCX: Add external thermistor support (thermistor sold separately)
Dry contact input Runtime MDT, Line powered TW-170LC-RC(I) Same functions as battery models but uses external DC 2.5 to 3.3V external power source

Usage

The Runtime MDTs connect across the 24VAC terminals of a typical thermostat control signal, typically at the baseboard heating zone valve. Can also be connected at the thermostat across the 24VAC C (Common) signal and the W (White) control signal. The polarity of the connection does not matter. A typical wiring diagram is shown here:

Captura de pantalla 2024-02-02 a la(s) 12.19.39 p. m.

Whenever the thermostat energizes the valve, the MDT will increment a “Seconds” runtime counter. The units for the runtime count can easily be changed to Minutes or Hours from within the Tehama software using the count factor on the Sensor View -> General Configuration tab. For minutes enter 0.0166667 (1/60). For Hours enter .00027778 (1/3600).

The unit samples the circuit every 30 seconds and will stop or start counting if the circuit state has changed. The sampling will take place even if the MDT has been manually turned off. If a unit is off, but it detects the voltage associated with an active circuit, the MDT will turn on and begin to transmit its data every hour.

If an MDT is on and transmitting, but detects that it is no longer connected to an active circuit, it will send an indication of circuit break and the CIT will display Disconnected in the Runtime Count field.

Wiring Instructions

TW-160B-R and TW-170B-R, 24VAC Runtime version

CIT 24VAC input Runtime MDT Standard

TW-160B-RC and TW-170B-RC, dry contact/relay input Runtime version

CIT Dry contact input Runtime MDT Standard

Wiring, TW-140B-R (Manufactured before Q4, 2016)

CIT 24VAC input Runtime MDT Standard-v2016

Connector Specifications

320-021-12-karson

TW-160/170 Removable Connector Specs:

Used on all TW-160/165 MDTs Pulse MDTs. Connector is compatible with other transmitters and some meters on the market.

  • Wire size (solid/stranded): 14 to 22 AWG
  • Strip Length: 1/4 inch (6mm)
  • Blade Type: 2.5mm Flat
Download the Data Sheet